Special Offers! Enjoy Up To 10% Discount!     >>Shop Now

T-AC03 T-AC04 Access Control Keypad FAQ

T-AC03 T-AC04 Access Control Keypad FAQ

T-AC03 T-AC04 Access Control Keypad FAQ

Q: Where can I get a manual of the A-TC03/T-AC04 keypad?

A: You could download the manual from Retekess official website: Download

Q: How do we program the RFID cards?

A: Enter Programming mode by pressing * then enter the Master Code, then press #, then press *,
Next, Press 1, then swipe card across the front of the keypad, then press #
To keep entering cards, Press 1, swipe the next card across the front of the keypad, then press # and continue to repeat the process until you have entered all the cards you want to enter.

Q: Can cards be deleted from this keypad?

A: Yes. It's a built in controller, so you can add/delete directly from the device. If using in Wiegand mode, you would need to manage the cards from your own controller

Q: Can I configure multiply pin codes and change some/all of them easily?

A: Yes, you can add multiple pin codes according to the instructions. And If you use prox cards with it, each card can have an access code with it.

Q: How to remove pin code from system?

A: 1. to enter the programming mode: *Master code(default 999999)#
2. to enter: 2 user ID number # for a PIN user or 2 Read card # for a card user

Q: How do I reset master code if I forgot mine?

A: If you want to reset master code, you need to reset to factory default according to the following instruction

  1. Disconnect power from the unit.
  2. Press and hold # key whilst powering the unit back up.
  3. On hearing two "Di" release # key, system is now back to factory settings. Then the default factory master code is 999999.

Q: Does it support dry contacts?

A: Yes, it does. The access control keypad has an internal relay with Common, NO and NC.

Q: Are the purple and blue wires normally open dry contact?

A: Yes, purple and blue are NO according to the spec sheet

Q: Can the keypad connect to Access Control?

A: Generically, yes. It has the wires for connection to a Weigand protocol access control system, which is the majority of them.

Q: Can we use this for elevator door entrance as well?

A: Yes, you can

Q: What is the length of the wiring cable to go through a wall?

A: The jacketed length of the cable is 9 inches. The individual wires extend another 2 1/2 inches


Comments

Comment user

Guest

Is the exit button supposed to be Normally Open or Normally Closed?

Comment user

Adam

I bought a retekes t-ac04 according to the description, it can be connected to the alarm, but after delivery it turns out that there is no gray wire and 12 only 10 cables, the drawing "La méthode d'installation est simple" how should I do it, or will we find a solution

Comment user

Guest

Hello, I have connected the reader to my Access controller via the Wiegand connection but data is being sent to my system as soon as a press a digit. The reader is not waiting for me to enter the full pin and then press the # key.

Comment user

Guest

How can i disable the light and the signal? Is this possible to disable via *.....# Code?

Comment user

dave

How do I activate/turn on Wiegand Mode for the T-AC04/

Comment user

Guest

How do I activate/turn on Wiegand Mode for the T-AC04?

Comment user

Guest

The keypad was working fine until it sometimes goes from blinking red to solid red and not operable. What does this mean?

Comment user

pasquale de rosa

posso usare due tastiere t-ac04 per entrare e uscire dal garage con un solo rfdi

Comment user

Guest

How do I wire a keypad inside and outside the door?

Comment user

Guest

Do you have a wiring diagramme that would enable me to fit a keypad inside and out?

Comment user

Guest

We have a T-AC03 T-AC04 Access Control Keypad How do we change the 4 digit code using the keypad Thanks

Comment author

Author

Hello, you could check the manual for the details: https://www.retekess.com/Assets/resource/Access-Control-System/T-AC03-EN-DE-FR-IT-ES.pdf, any other questions, just feel free to email us with the Order ID of the purchase.

Leave a comment

0