Special Offers! Enjoy Up To 10% Discount!     >>Shop Now

T-AC03 T-AC04 Access Control Keypad FAQ

T-AC03 T-AC04 Access Control Keypad FAQ

T-AC03 T-AC04 Access Control Keypad FAQ

Q: Where can I get a manual of the A-TC03/T-AC04 keypad?

A: You could download the manual from Retekess official website: Download

Q: How do we program the RFID cards?

A: Enter Programming mode by pressing * then enter the Master Code, then press #, then press *,
Next, Press 1, then swipe card across the front of the keypad, then press #
To keep entering cards, Press 1, swipe the next card across the front of the keypad, then press # and continue to repeat the process until you have entered all the cards you want to enter.

Q: Can cards be deleted from this keypad?

A: Yes. It's a built in controller, so you can add/delete directly from the device. If using in Wiegand mode, you would need to manage the cards from your own controller

Q: Can I configure multiply pin codes and change some/all of them easily?

A: Yes, you can add multiple pin codes according to the instructions. And If you use prox cards with it, each card can have an access code with it.

Q: How to remove pin code from system?

A: 1. to enter the programming mode: *Master code(default 999999)#
2. to enter: 2 user ID number # for a PIN user or 2 Read card # for a card user

Q: How do I reset master code if I forgot mine?

A: If you want to reset master code, you need to reset to factory default according to the following instruction

  1. Disconnect power from the unit.
  2. Press and hold # key whilst powering the unit back up.
  3. On hearing two "Di" release # key, system is now back to factory settings. Then the default factory master code is 999999.

Q: Does it support dry contacts?

A: Yes, it does. The access control keypad has an internal relay with Common, NO and NC.

Q: Are the purple and blue wires normally open dry contact?

A: Yes, purple and blue are NO according to the spec sheet

Q: Can the keypad connect to Access Control?

A: Generically, yes. It has the wires for connection to a Weigand protocol access control system, which is the majority of them.

Q: Can we use this for elevator door entrance as well?

A: Yes, you can

Q: What is the length of the wiring cable to go through a wall?

A: The jacketed length of the cable is 9 inches. The individual wires extend another 2 1/2 inches


Comments

Comment user

Guest

I am wondering if it is possible for the relay to open on the code and close on the code holding until the code is next entered? Thank you

Comment user

Mikel

I am going to install the keypad in parallel with a 24V voice based access control. Although the AC03 will be driven with 12V, is it possible to connect the 24V to the AC03 switch port? Thank you

Comment author

Author

Hi Mikel, no, it only works with DC 12V±10%

Comment user

Eliot

Hi, is it possible to program a RFID card for only ONE USE in 10 minutes? I don´t want an user activating continously the system.

Comment user

Guest

What wires control the light on the keypad? Thanks.

Comment author

Author

Hi, thank you for using the Retekess system. The flashing red indicator light of the keyboard cannot be turned off. If you have other questions, please feel free to contact us by email at support@retekess.com. We will provide the solution to you.

Comment user

Guest

Can I turn off the tone with the T-AC04? It is very annoying for the neighbors. Or can I at least reduce the volume?

Comment author

Author

Hi. Thanks for using the Retekess system. The sound of T-AC04 can't be turn off. If you have any other questions or needs, please contact us by email when you are free. support@retekess.com

Comment user

Installer - Tim

Can I configure the output of the Wiegand format? (i.e.. Send data with each key press Wiegand 8-Bit, Nibbles, Complemented)? Thanks, TimP

Comment author

Author

Hi Tim, Retekess Access Control Keypad has the unit operating as a Wiegand Output Reader. In this mode, the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input.

Comment user

Michael

Hi, Is it possible to turn off the access control and just have the Wiegand output? Thanks

Comment user

Guest

I’m looking fir a key pays that I can tie to a contactor for a stove in a nursing home. Can you set the NO trigger for a 2 hr duration or how long can it be open for? Also during the activation can you hit a command to close or cancel its function? My phone number is +14109633999 if you wanted to call thx

Comment author

Author

Hello, thanks for contact Retekess. It is regret to inform you that we have no such a keypad meets your requirements. Best Regards

Leave a comment

0